BELOW THE SURFACE. WITHIN SPEC.

Submersible Hydrostatic Level Transmitters & Tank/Well Liquid Level Sensors

Start with the liquid. Specify the right probe, pressure span and vented cable for water tanks, wastewater, chemical liquids and deep wells.

4–20 mA / voltage / Modbus options316L & PTFE configuration paths
THE MEASUREMENT CHAINSLV / ENGINEERING NOTE 01
Conceptual cutaway showing vented cable, atmospheric reference tube, piezoresistive cell and probe nose
Functional concept — not a released assembly drawing. Materials and geometry depend on configuration.
01Choose the wetted materials
02Size the liquid-head range
03Keep the atmospheric vent dry

ONE PRINCIPLE. FOUR CONFIGURATION PATHS.

A probe for the liquid.
A cable for the installation.

Single-probe hydrostatic measurement for atmospheric vessels and wells. Configuration codes begin with SLV-.

THE SMALL TUBE THAT MAKES THE DIFFERENCE

Pressure at the probe.
Atmosphere at the vent.

A submersible gauge-pressure sensor references the atmosphere through a small tube inside its cable. A wet or blocked vent can introduce measurement error and damage the assembly.

Build the termination kit ↗
01

Leave a breathable reference

Keep the cable end above flood level; never seal or kink its vent.

02

Control moisture

Specify a suitable vented box and serviceable desiccant. Inspect it for site humidity.

03

Support the suspended load

Use rated strain relief; keep weight off conductors and vent tubing.

KEEP THE WHOLE LOOP IN VIEW

From probe selection to dry cable termination.

BEFORE THE RFQ

Three details that change the specification.

Is well depth the same as measuring range?

No. Measuring range covers liquid head above the sensor. Installation depth, cable route and service allowance determine cable length; they also affect pressure and suspended-load requirements.

Does a PTFE housing approve the probe for every acid?

No. Confirm chemical concentration, temperature, diaphragm, seals, cable jacket and all other wetted parts together.

Can I directly replace another brand?

Compare span, output, wiring, dimensions, materials, venting and approvals against the exact installed part. A product family or similar appearance is not proof of interchangeability.

START WITH THE INSTALLATION

Liquid. Depth. Cable. Signal.

Send these four inputs to start a configuration review.

Request an engineering quote ↗